{"schemaVersion":"1.0","publishedOnly":true,"generatedAt":"2026-11-16T20:22:30.791Z","rules":[{"id":"c7eed6ec-e1e8-479e-b6bb-d9f148b480a1","ruleKey":"aci-cold-weather","revision":"ACI 306R-16","category":"Concrete and masonry","activityKey":"concrete-placement","activity":"Concrete placement and protection planning","jurisdiction":"United States","ruleClass":"external_guidance_interpretation","technicalBasis":"Cold-weather guide definition used as planning prompt, not a universal prohibition or automatically binding contract requirement.","sourceReferences":[{"url":"https://www.concrete.org/Portals/0/Files/PDF/University/306R-16_excerpt.pdf","title":"ACI 306R-16 Guide to Cold Weather Concreting · excerpt","version":"ACI 306R-16","publisher":"American Concrete Institute","sourceType":"industry guide","jurisdiction":"United States"}],"criteria":{"kind":"cold_weather_guide","generic":true,"thresholdC":4},"publishedDetermination":{"scope":"Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.","outputs":["recommended","not_recommended","conditional","insufficient_data"]},"effectiveAt":null,"publishedAt":"2026-11-05T17:01:27.020Z","legacyImported":true},{"id":"135cafb0-7a86-4b14-b451-a885d6ee5794","ruleKey":"euclid-duralprep-ac","revision":"Rev. 03.25","category":"Concrete and masonry","activityKey":"concrete-placement","activity":"Concrete placement and repair bonding","jurisdiction":"United States","ruleClass":"manufacturer_requirement","technicalBasis":"Official US TDS. Ambient and surface application temperatures 45–90°F (7–32°C); material temperature at least 45°F (7°C) and rising. Concrete substrate must be saturated surface-dry with no standing water; if project specifications require quantitative pull-off testing, the TDS states at least 250 psi (1.7 MPa).","sourceReferences":[{"url":"https://www.euclidchemical.com/fileshare/ProductFiles/TDS/Duralprep_AC.pdf","title":"DURALPREP A.C. Technical Data Sheet · US","version":"Rev. 03.25","publisher":"The Euclid Chemical Company","sourceType":"manufacturer technical data sheet","jurisdiction":"United States"}],"criteria":{"kind":"duralprep_ac","maxC":32,"minC":7,"minMaterialC":7,"steelPreparation":"SSPC SP10 near-white","pullOffIfSpecified":true,"pullOffStrengthPsi":250,"materialMustBeRising":true},"publishedDetermination":{"scope":"Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.","outputs":["recommended","not_recommended","conditional","insufficient_data"]},"effectiveAt":null,"publishedAt":"2026-11-05T17:01:27.388Z","legacyImported":true},{"id":"b6eccf46-71a8-4ec4-a61e-e824ceee0ed0","ruleKey":"sika-sikafloor-264","revision":"September 2026, Version 08.05","category":"Flooring and surface systems","activityKey":"flooring-and-surface-systems:epoxy-flooring","activity":"Epoxy flooring","jurisdiction":"United States","ruleClass":"manufacturer_requirement","technicalBasis":"Current official U.S. product sheet. Application limits include ambient and substrate temperatures 10–30°C; substrate at least 3°C above dew point; ambient RH at most 85%; concrete moisture at most 4% by mass measured with a Tramex meter; ASTM F2170 concrete RH at most 85%. The sheet requires onsite measurements and repeat recording at least every 3 hours or when conditions change. Weather alone cannot establish compliance.","sourceReferences":[{"url":"https://usa.sika.com/dam/dms/us01/g/sikafloor_-264.pdf","title":"Sikafloor-264 Product Data Sheet","version":"September 2026, Version 08.05","publisher":"Sika Corporation","sourceType":"manufacturer product data sheet","jurisdiction":"United States"}],"criteria":{"kind":"epoxy_floor_coating","maxAmbientC":30,"minAmbientC":10,"maxSubstrateC":30,"minSubstrateC":10,"dewPointClearanceC":3,"maxAmbientRhPercent":85,"maxConcreteRhPercent":85,"measurementIntervalHours":3,"maxConcreteMoisturePercent":4},"publishedDetermination":{"scope":"Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.","outputs":["recommended","not_recommended","conditional","insufficient_data"]},"effectiveAt":null,"publishedAt":"2026-11-05T17:01:27.209Z","legacyImported":true},{"id":"44e10e3f-aa53-4331-9718-1f55a1aa5d4d","ruleKey":"bm-element-guard-0765","revision":"0765 TDS, US issue","category":"Painting and coatings","activityKey":"exterior-painting","activity":"Exterior painting","jurisdiction":"United States","ruleClass":"manufacturer_requirement","technicalBasis":"Surface temperature is required. Forecast air temperature is not surface temperature.","sourceReferences":[{"url":"https://media.benjaminmoore.com/WebServices/prod/assets/production/datasheets/TDS_0765/765_TDS_US.pdf","title":"Benjamin Moore Element Guard 0765 Product Data Sheet","version":"0765 TDS, US issue","publisher":"Benjamin Moore","sourceType":"manufacturer data sheet","jurisdiction":"United States"}],"criteria":{"kind":"air_screen_surface_required","maxSurfaceC":37.8,"minSurfaceC":1.7},"publishedDetermination":{"scope":"Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.","outputs":["recommended","not_recommended","conditional","insufficient_data"]},"effectiveAt":null,"publishedAt":"2026-11-05T17:01:27.020Z","legacyImported":true},{"id":"548a9c92-8d68-4b63-8b28-15d2da5fd985","ruleKey":"sherwin-duration-exterior-k33","revision":"March 2026 · PDS 102.14B","category":"Painting and coatings","activityKey":"exterior-painting","activity":"Exterior painting","jurisdiction":"United States","ruleClass":"manufacturer_requirement","technicalBasis":"Official manufacturer PDS, revision printed 3/2026. States: do not apply at air or surface temperatures below 35°F (1.7°C), or when air/surface may fall below 35°F within 48 hours. Air, surface, and material must be above 35°F and at least 5°F above dew point. Avoid use when rain or snow is expected within 2–3 hours. Large expanses of metal siding require air, surface, and material temperatures of at least 50°F (10°C); this product/weather rule does not assess that special substrate case.","sourceReferences":[{"url":"https://www.sherwin-williams.com/document/PDS/en/035777132685/","title":"Duration Exterior Acrylic Satin Product Data Sheet · K33-Series","version":"March 2026 · PDS 102.14B","publisher":"The Sherwin-Williams Company","sourceType":"manufacturer product data sheet","jurisdiction":"United States"}],"criteria":{"kind":"sherwin_duration_exterior","minC":1.7,"rainScreenHours":3,"dewPointClearanceC":2.8,"metalSubstrateMinC":10,"temperatureLookaheadHours":48},"publishedDetermination":{"scope":"Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.","outputs":["recommended","not_recommended","conditional","insufficient_data"]},"effectiveAt":null,"publishedAt":"2026-11-05T17:01:27.562Z","legacyImported":true},{"id":"b1a8643e-5151-43e1-b162-66ad5fc499a1","ruleKey":"gaf-tab-r133","revision":"TAB-R-133, Rev. 2024","category":"Roofing","activityKey":"asphalt-shingle-installation","activity":"Asphalt shingle installation","jurisdiction":"United States","ruleClass":"manufacturer_requirement","technicalBasis":"Above 40 F noted as easier handling; no practical temperature limit if appropriate precautions are followed.","sourceReferences":[{"url":"https://www.gaf.com/en-us/document-library/documents/technical-bulletins-%26-notes/r-133-temperature-extremes-%26-fiberglass-asphalt-shingles.pdf","title":"GAF TAB-R-133 Temperature Extremes & Fiberglass Asphalt Shingles","version":"TAB-R-133, Rev. 2024","publisher":"GAF","sourceType":"manufacturer technical bulletin","jurisdiction":"United States"}],"criteria":{"kind":"cold_handling_context","handlingThresholdC":4.4},"publishedDetermination":{"scope":"Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.","outputs":["recommended","not_recommended","conditional","insufficient_data"]},"effectiveAt":null,"publishedAt":"2026-11-05T17:01:27.020Z","legacyImported":true},{"id":"9771f855-56ed-4ffd-8592-84af5677c5a9","ruleKey":"sika-construction-sealant","revision":"August 2023, Version 01.01","category":"Waterproofing and sealants","activityKey":"exterior-joint-sealing","activity":"Exterior joint sealing","jurisdiction":"Canada","ruleClass":"manufacturer_requirement","technicalBasis":"Ambient and substrate application range 4–38 C; surfaces must be clean, sound, dry, and frost-free.","sourceReferences":[{"url":"https://can.sika.com/dms/getdocument.get/b8fb9551-30e3-4cd1-94f7-82a14007d6c9/sikaflex-constructionsealant.pdf","title":"Sika Canada Sikaflex Construction Sealant Product Data Sheet","version":"August 2023, Version 01.01","publisher":"Sika Canada","sourceType":"manufacturer product data sheet","jurisdiction":"Canada"}],"criteria":{"kind":"ambient_range_surface_required","maxC":38,"minC":4},"publishedDetermination":{"scope":"Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.","outputs":["recommended","not_recommended","conditional","insufficient_data"]},"effectiveAt":null,"publishedAt":"2026-11-05T17:01:27.020Z","legacyImported":true},{"id":"ef257982-2a27-4f6f-9216-adac182bcde4","ruleKey":"tremco-dymonic-fc","revision":"DFC-DS/1026","category":"Waterproofing and sealants","activityKey":"exterior-joint-sealing","activity":"Exterior joint sealing","jurisdiction":"North America","ruleClass":"manufacturer_requirement","technicalBasis":"Current official TDS downloaded from Tremco resource library; document identifier DFC-DS/1026. It says do not apply over damp or contaminated surfaces and not to use under polyurethane deck coatings. The sheet refers readers to Tremco’s website for the most current product data sheets.","sourceReferences":[{"url":"https://www.tremcosealants.com/resource/download/dymonic_fc_ds.pdf","title":"Dymonic FC Technical Data Sheet","version":"DFC-DS/1026","publisher":"Tremco Sealants","sourceType":"manufacturer technical data sheet","jurisdiction":"North America"}],"criteria":{"kind":"tremco_dymonic_fc","maxC":32,"minC":4,"supportingSources":[{"url":"https://www.tremcosealants.com/products/dymonic-fc","title":"Tremco Dymonic FC official product page","product":"Dymonic FC","version":"Accessed 2026-11-02","sourceType":"manufacturer product page","jurisdiction":"North America","manufacturer":"Tremco"}]},"publishedDetermination":{"scope":"Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.","outputs":["recommended","not_recommended","conditional","insufficient_data"]},"effectiveAt":null,"publishedAt":"2026-11-05T17:01:27.925Z","legacyImported":true},{"id":"c1645d6e-bfb5-4302-9254-4ac284c8a168","ruleKey":"mapei-mapelastic-aquadefense","revision":"Edition October 7, 2025; MK 3002103 (25-1788)","category":"Waterproofing and sealants","activityKey":"liquid-membrane","activity":"Liquid membrane installation","jurisdiction":"North America","ruleClass":"manufacturer_requirement","technicalBasis":"Official North American TDS. Substrate and room must stay 45–95°F (7–35°C) during application and for at least 24 hours afterward. Maximum substrate moisture is 8 lb/1,000 ft²/24 h by ASTM F1869 or 85% RH by probes; do not use with excessive moisture or negative hydrostatic pressure. Protect from foot traffic, rain, and freezing for 24 hours. Forecast air cannot establish substrate or room measurements, moisture, or protection.","sourceReferences":[{"url":"https://cdnmedia.mapei.com/docs/librariesprovider65/products-documents/1_3002103_mapelastic-aquadefense_en-ca_14db312e5e76423d88100935240e248a.pdf?sfvrsn=d4b6eeeb_0","title":"Mapelastic AquaDefense Technical Data Sheet · Canada / North America","version":"Edition October 7, 2025; MK 3002103 (25-1788)","publisher":"MAPEI Corporation","sourceType":"manufacturer technical data sheet","jurisdiction":"North America"}],"criteria":{"kind":"mapelastic_aquadefense","maxC":35,"minC":7,"maxSourceF":95,"minSourceF":45,"protectionHours":24,"maxInSituRhPercent":85,"maxMoistureLbPer1000SqFt24h":8},"publishedDetermination":{"scope":"Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.","outputs":["recommended","not_recommended","conditional","insufficient_data"]},"effectiveAt":null,"publishedAt":"2026-11-05T17:01:27.388Z","legacyImported":true}]}