Weather Standard recommendations are advisory interpretations. Manufacturer requirements, government guidance, Weather Standard criteria, and forecast-derived inputs are identified separately. Publication does not establish regulatory authority, standards-body recognition, insurer endorsement, or onsite compliance.
Published revisions
Concrete and masonry · external guidance interpretation
Concrete placement and protection planning
Rule revision: ACI 306R-16 · Applies in: United States
Cold-weather guide definition used as planning prompt, not a universal prohibition or automatically binding contract requirement.
Effective: date not stated · Published: Thu Nov 05 2026 17:01:27 GMT+0000 (Coordinated Universal Time)
Criteria, determination and source records
{
"criteria": {
"kind": "cold_weather_guide",
"generic": true,
"thresholdC": 4
},
"publishedDetermination": {
"scope": "Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.",
"outputs": [
"recommended",
"not_recommended",
"conditional",
"insufficient_data"
]
}
}ACI 306R-16 Guide to Cold Weather Concreting · excerpt · ACI 306R-16 · American Concrete Institute
Legacy verified library entry. No independent external expert approval is recorded for this imported revision. legacy_internal_source_verification; no external expert approval is recorded by this migration
Concrete and masonry · manufacturer requirement
Concrete placement and repair bonding
Rule revision: Rev. 03.25 · Applies in: United States
Official US TDS. Ambient and surface application temperatures 45–90°F (7–32°C); material temperature at least 45°F (7°C) and rising. Concrete substrate must be saturated surface-dry with no standing water; if project specifications require quantitative pull-off testing, the TDS states at least 250 psi (1.7 MPa).
Effective: date not stated · Published: Thu Nov 05 2026 17:01:27 GMT+0000 (Coordinated Universal Time)
Criteria, determination and source records
{
"criteria": {
"kind": "duralprep_ac",
"maxC": 32,
"minC": 7,
"minMaterialC": 7,
"steelPreparation": "SSPC SP10 near-white",
"pullOffIfSpecified": true,
"pullOffStrengthPsi": 250,
"materialMustBeRising": true
},
"publishedDetermination": {
"scope": "Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.",
"outputs": [
"recommended",
"not_recommended",
"conditional",
"insufficient_data"
]
}
}DURALPREP A.C. Technical Data Sheet · US · Rev. 03.25 · The Euclid Chemical Company
Legacy verified library entry. No independent external expert approval is recorded for this imported revision. legacy_internal_source_verification; no external expert approval is recorded by this migration
Flooring and surface systems · manufacturer requirement
Epoxy flooring
Rule revision: September 2026, Version 08.05 · Applies in: United States
Current official U.S. product sheet. Application limits include ambient and substrate temperatures 10–30°C; substrate at least 3°C above dew point; ambient RH at most 85%; concrete moisture at most 4% by mass measured with a Tramex meter; ASTM F2170 concrete RH at most 85%. The sheet requires onsite measurements and repeat recording at least every 3 hours or when conditions change. Weather alone cannot establish compliance.
Effective: date not stated · Published: Thu Nov 05 2026 17:01:27 GMT+0000 (Coordinated Universal Time)
Criteria, determination and source records
{
"criteria": {
"kind": "epoxy_floor_coating",
"maxAmbientC": 30,
"minAmbientC": 10,
"maxSubstrateC": 30,
"minSubstrateC": 10,
"dewPointClearanceC": 3,
"maxAmbientRhPercent": 85,
"maxConcreteRhPercent": 85,
"measurementIntervalHours": 3,
"maxConcreteMoisturePercent": 4
},
"publishedDetermination": {
"scope": "Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.",
"outputs": [
"recommended",
"not_recommended",
"conditional",
"insufficient_data"
]
}
}Sikafloor-264 Product Data Sheet · September 2026, Version 08.05 · Sika Corporation
Legacy verified library entry. No independent external expert approval is recorded for this imported revision. legacy_internal_source_verification; no external expert approval is recorded by this migration
Painting and coatings · manufacturer requirement
Exterior painting
Rule revision: 0765 TDS, US issue · Applies in: United States
Surface temperature is required. Forecast air temperature is not surface temperature.
Effective: date not stated · Published: Thu Nov 05 2026 17:01:27 GMT+0000 (Coordinated Universal Time)
Criteria, determination and source records
{
"criteria": {
"kind": "air_screen_surface_required",
"maxSurfaceC": 37.8,
"minSurfaceC": 1.7
},
"publishedDetermination": {
"scope": "Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.",
"outputs": [
"recommended",
"not_recommended",
"conditional",
"insufficient_data"
]
}
}Benjamin Moore Element Guard 0765 Product Data Sheet · 0765 TDS, US issue · Benjamin Moore
Legacy verified library entry. No independent external expert approval is recorded for this imported revision. legacy_internal_source_verification; no external expert approval is recorded by this migration
Painting and coatings · manufacturer requirement
Exterior painting
Rule revision: March 2026 · PDS 102.14B · Applies in: United States
Official manufacturer PDS, revision printed 3/2026. States: do not apply at air or surface temperatures below 35°F (1.7°C), or when air/surface may fall below 35°F within 48 hours. Air, surface, and material must be above 35°F and at least 5°F above dew point. Avoid use when rain or snow is expected within 2–3 hours. Large expanses of metal siding require air, surface, and material temperatures of at least 50°F (10°C); this product/weather rule does not assess that special substrate case.
Effective: date not stated · Published: Thu Nov 05 2026 17:01:27 GMT+0000 (Coordinated Universal Time)
Criteria, determination and source records
{
"criteria": {
"kind": "sherwin_duration_exterior",
"minC": 1.7,
"rainScreenHours": 3,
"dewPointClearanceC": 2.8,
"metalSubstrateMinC": 10,
"temperatureLookaheadHours": 48
},
"publishedDetermination": {
"scope": "Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.",
"outputs": [
"recommended",
"not_recommended",
"conditional",
"insufficient_data"
]
}
}Duration Exterior Acrylic Satin Product Data Sheet · K33-Series · March 2026 · PDS 102.14B · The Sherwin-Williams Company
Legacy verified library entry. No independent external expert approval is recorded for this imported revision. legacy_internal_source_verification; no external expert approval is recorded by this migration
Roofing · manufacturer requirement
Asphalt shingle installation
Rule revision: TAB-R-133, Rev. 2024 · Applies in: United States
Above 40 F noted as easier handling; no practical temperature limit if appropriate precautions are followed.
Effective: date not stated · Published: Thu Nov 05 2026 17:01:27 GMT+0000 (Coordinated Universal Time)
Criteria, determination and source records
{
"criteria": {
"kind": "cold_handling_context",
"handlingThresholdC": 4.4
},
"publishedDetermination": {
"scope": "Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.",
"outputs": [
"recommended",
"not_recommended",
"conditional",
"insufficient_data"
]
}
}GAF TAB-R-133 Temperature Extremes & Fiberglass Asphalt Shingles · TAB-R-133, Rev. 2024 · GAF
Legacy verified library entry. No independent external expert approval is recorded for this imported revision. legacy_internal_source_verification; no external expert approval is recorded by this migration
Waterproofing and sealants · manufacturer requirement
Exterior joint sealing
Rule revision: August 2023, Version 01.01 · Applies in: Canada
Ambient and substrate application range 4–38 C; surfaces must be clean, sound, dry, and frost-free.
Effective: date not stated · Published: Thu Nov 05 2026 17:01:27 GMT+0000 (Coordinated Universal Time)
Criteria, determination and source records
{
"criteria": {
"kind": "ambient_range_surface_required",
"maxC": 38,
"minC": 4
},
"publishedDetermination": {
"scope": "Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.",
"outputs": [
"recommended",
"not_recommended",
"conditional",
"insufficient_data"
]
}
}Sika Canada Sikaflex Construction Sealant Product Data Sheet · August 2023, Version 01.01 · Sika Canada
Legacy verified library entry. No independent external expert approval is recorded for this imported revision. legacy_internal_source_verification; no external expert approval is recorded by this migration
Waterproofing and sealants · manufacturer requirement
Exterior joint sealing
Rule revision: DFC-DS/1026 · Applies in: North America
Current official TDS downloaded from Tremco resource library; document identifier DFC-DS/1026. It says do not apply over damp or contaminated surfaces and not to use under polyurethane deck coatings. The sheet refers readers to Tremco’s website for the most current product data sheets.
Effective: date not stated · Published: Thu Nov 05 2026 17:01:27 GMT+0000 (Coordinated Universal Time)
Criteria, determination and source records
{
"criteria": {
"kind": "tremco_dymonic_fc",
"maxC": 32,
"minC": 4,
"supportingSources": [
{
"url": "https://www.tremcosealants.com/products/dymonic-fc",
"title": "Tremco Dymonic FC official product page",
"product": "Dymonic FC",
"version": "Accessed 2026-11-02",
"sourceType": "manufacturer product page",
"jurisdiction": "North America",
"manufacturer": "Tremco"
}
]
},
"publishedDetermination": {
"scope": "Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.",
"outputs": [
"recommended",
"not_recommended",
"conditional",
"insufficient_data"
]
}
}Dymonic FC Technical Data Sheet · DFC-DS/1026 · Tremco Sealants
Legacy verified library entry. No independent external expert approval is recorded for this imported revision. legacy_internal_source_verification; no external expert approval is recorded by this migration
Waterproofing and sealants · manufacturer requirement
Liquid membrane installation
Rule revision: Edition October 7, 2025; MK 3002103 (25-1788) · Applies in: North America
Official North American TDS. Substrate and room must stay 45–95°F (7–35°C) during application and for at least 24 hours afterward. Maximum substrate moisture is 8 lb/1,000 ft²/24 h by ASTM F1869 or 85% RH by probes; do not use with excessive moisture or negative hydrostatic pressure. Protect from foot traffic, rain, and freezing for 24 hours. Forecast air cannot establish substrate or room measurements, moisture, or protection.
Effective: date not stated · Published: Thu Nov 05 2026 17:01:27 GMT+0000 (Coordinated Universal Time)
Criteria, determination and source records
{
"criteria": {
"kind": "mapelastic_aquadefense",
"maxC": 35,
"minC": 7,
"maxSourceF": 95,
"minSourceF": 45,
"protectionHours": 24,
"maxInSituRhPercent": 85,
"maxMoistureLbPer1000SqFt24h": 8
},
"publishedDetermination": {
"scope": "Legacy published determination from the verified requirement record; weather screening does not establish onsite compliance.",
"outputs": [
"recommended",
"not_recommended",
"conditional",
"insufficient_data"
]
}
}Mapelastic AquaDefense Technical Data Sheet · Canada / North America · Edition October 7, 2025; MK 3002103 (25-1788) · MAPEI Corporation
Legacy verified library entry. No independent external expert approval is recorded for this imported revision. legacy_internal_source_verification; no external expert approval is recorded by this migration
Under development
Winter Risk methodology remains unpublished. Preventive anti-icing, reactive de-icing, mechanical snow removal, sidewalk treatment, and parking-lot treatment do not have Weather Standard treatment thresholds. Air temperature is not treated as pavement temperature. Site, surface, material, method, moisture, precipitation phase, and forecast uncertainty require technical and field validation before any criteria can be published.
Read methodology and limits
Machine-readable published rules